Engineering and Related Technologies · AQF Level 3
Certificate III in Air Conditioning and Refrigeration
UEE32225
Career outcomes
Filter providers
Providers offering this course
Showing 4 of 26
Showing 4 of 26
Units of competency in this qualification
Each unit is nationally recognised. Open a unit to see what it covers and which other qualifications include it.
- Unit of competencyCORE
Apply work health and safety regulations, codes and practices in the workplace
UEECD0007
Delivered by RTOsVaries by providerView unit - Unit of competencyCORE
Document and apply measures to control WHS risks associated with electrotechnology work
UEECD0016
Delivered by RTOsVaries by providerView unit - Unit of competencyCORE
Fabricate, assemble and dismantle utilities industry components
UEECD0019
Delivered by RTOsVaries by providerView unit - Unit of competencyCORE
Fix and secure electrotechnology equipment
UEECD0020
Delivered by RTOsVaries by providerView unit - Unit of competencyCORE
Solve problems in ELV single path circuits
UEECD0042
Delivered by RTOsVaries by providerView unit - Unit of competencyCORE
Use drawings, diagrams, schedules, standards, codes and specifications
UEECD0051
Delivered by RTOsVaries by providerView unit - Unit of competencyCORE
Participate in refrigeration and air conditioning work and competency development activities
UEECO0010
Delivered by RTOsVaries by providerView unit - Unit of competencyCORE
Diagnose and rectify faults in air conditioning and refrigeration control systems
UEERA0031
Delivered by RTOsVaries by providerView unit - Unit of competencyCORE
Establish the basic operating conditions of air conditioning systems
UEERA0035
Delivered by RTOsVaries by providerView unit - Unit of competencyCORE
Establish the basic operating conditions of vapour compression systems
UEERA0036
Delivered by RTOsVaries by providerView unit - Unit of competencyCORE
Find and rectify faults in single phase motors and associated controls
UEERA0044
Delivered by RTOsVaries by providerView unit - Unit of competencyCORE
Find and rectify faults in three phase motors and associated controls
UEERA0045
Delivered by RTOsVaries by providerView unit - Unit of competencyCORE
Install refrigerant pipe work, flow controls and accessories
UEERA0050
Delivered by RTOsVaries by providerView unit - Unit of competencyCORE
Install, commission, service and maintain low temperature systems
UEERA0052
Delivered by RTOsVaries by providerView unit - Unit of competencyCORE
Install, commission, service and maintain medium temperature systems
UEERA0053
Delivered by RTOsVaries by providerView unit - Unit of competencyCORE
Prepare and connect refrigerant tubing and fittings
UEERA0059
Delivered by RTOsVaries by providerView unit - Unit of competencyCORE
Recover and charge refrigerants
UEERA0062
Delivered by RTOsVaries by providerView unit - Unit of competencyCORE
Safely handle refrigerants and lubricants
UEERA0079
Delivered by RTOsVaries by providerView unit - Unit of competencyCORE
Select refrigerant piping, accessories and associated controls
UEERA0081
Delivered by RTOsVaries by providerView unit - Unit of competencyCORE
Solve problems in low voltage refrigeration and air conditioning circuits
UEERA0092
Delivered by RTOsVaries by providerView unit - Unit of competencyCORE
Verify functionality and compliance of refrigeration and air conditioning installations
UEERA0094
Delivered by RTOsVaries by providerView unit - Unit of competencyCORE
Install, commission, service and maintain air conditioning systems
UEERA0099
Delivered by RTOsVaries by providerView unit - Unit of competencyCORE
Apply environmentally and sustainable procedures in the energy sector
UEERE0001
Delivered by RTOsVaries by providerView unit - Unit of competencyCORE
Attach cords and plugs to electrical equipment for connection to a single phase 230 Volt supply
UEERL0001
Delivered by RTOsVaries by providerView unit - Unit of competencyCORE
Attach cords, cables and plugs to electrical equipment for connection to 1000 V a.c. or 1500 V d.c.
UEERL0002
Delivered by RTOsVaries by providerView unit - Unit of competencyCORE
Disconnect - reconnect electrical equipment connected to low voltage (LV) installation wiring
UEERL0004
Delivered by RTOsVaries by providerView unit - Unit of competencyCORE
Locate and rectify faults in low voltage (LV) electrical equipment using set procedures
UEERL0005
Delivered by RTOsVaries by providerView unit - Unit of competencyELECTIVE
Deliver a service to customers
BSBOPS203
Delivered by RTOsVaries by providerView unit - Unit of competencyELECTIVE
Prepare to work safely in the construction industry
CPCWHS1001
Delivered by RTOsVaries by providerView unit - Unit of competencyELECTIVE
Provide cardiopulmonary resuscitation
HLTAID009
Delivered by RTOsVaries by providerView unit - Unit of competencyELECTIVE
Provide First Aid
HLTAID011
Delivered by RTOsVaries by providerView unit - Unit of competencyELECTIVE
Operate application software packages
ICTICT214
Delivered by RTOsVaries by providerView unit - Unit of competencyELECTIVE
Comply with scheduled and preventative maintenance program processes
UEECD0011
Delivered by RTOsVaries by providerView unit - Unit of competencyELECTIVE
Provide basic instruction in the use of electrotechnology apparatus
UEECD0035
Delivered by RTOsVaries by providerView unit - Unit of competencyELECTIVE
Maintain documentation
UEECO0002
Delivered by RTOsVaries by providerView unit - Unit of competencyELECTIVE
Provide quotations for installation or service jobs
UEECO0015
Delivered by RTOsVaries by providerView unit - Unit of competencyELECTIVE
Source and purchase material/parts for installation or service jobs
UEECO0017
Delivered by RTOsVaries by providerView unit - Unit of competencyELECTIVE
Develop, enter and verify discrete control programs for programmable controllers
UEEIC0013
Delivered by RTOsVaries by providerView unit - Unit of competencyELECTIVE
Apply safety awareness and legal requirements for ammonia refrigerant
UEERA0005
Delivered by RTOsVaries by providerView unit - Unit of competencyELECTIVE
Apply safety awareness and legal requirements for carbon dioxide refrigerant
UEERA0006
Delivered by RTOsVaries by providerView unit - Unit of competencyELECTIVE
Apply safety awareness and legal requirements for flammable refrigerants
UEERA0007
Delivered by RTOsVaries by providerView unit - Unit of competencyELECTIVE
Install and commission ammonia refrigeration systems, components and associated equipment
UEERA0046
Delivered by RTOsVaries by providerView unit - Unit of competencyELECTIVE
Install and commission carbon dioxide refrigeration systems, components and associated equipment
UEERA0047
Delivered by RTOsVaries by providerView unit - Unit of competencyELECTIVE
Install and commission flammable refrigerant air conditioning and refrigeration systems
UEERA0048
Delivered by RTOsVaries by providerView unit - Unit of competencyELECTIVE
Maintain microbial control of refrigeration and air conditioning systems
UEERA0054
Delivered by RTOsVaries by providerView unit - Unit of competencyELECTIVE
Operate ammonia refrigeration plant
UEERA0057
Delivered by RTOsVaries by providerView unit - Unit of competencyELECTIVE
Repair and service ammonia refrigeration systems
UEERA0065
Delivered by RTOsVaries by providerView unit - Unit of competencyELECTIVE
Repair and service carbon dioxide refrigeration systems
UEERA0066
Delivered by RTOsVaries by providerView unit - Unit of competencyELECTIVE
Repair and service secondary refrigeration systems
UEERA0067
Delivered by RTOsVaries by providerView unit - Unit of competencyELECTIVE
Repair and service self-contained carbon dioxide refrigeration and heat pump systems
UEERA0068
Delivered by RTOsVaries by providerView unit - Unit of competencyELECTIVE
Resolve problems in beverage dispensers
UEERA0069
Delivered by RTOsVaries by providerView unit - Unit of competencyELECTIVE
Resolve problems in central plant air conditioning systems
UEERA0070
Delivered by RTOsVaries by providerView unit - Unit of competencyELECTIVE
Resolve problems in dairy refrigeration systems
UEERA0071
Delivered by RTOsVaries by providerView unit - Unit of competencyELECTIVE
Resolve problems in hydronic systems
UEERA0072
Delivered by RTOsVaries by providerView unit - Unit of competencyELECTIVE
Resolve problems in ice making systems
UEERA0073
Delivered by RTOsVaries by providerView unit - Unit of competencyELECTIVE
Resolve problems in industrial refrigeration systems
UEERA0074
Delivered by RTOsVaries by providerView unit - Unit of competencyELECTIVE
Resolve problems in post-mix refrigeration systems
UEERA0075
Delivered by RTOsVaries by providerView unit - Unit of competencyELECTIVE
Resolve problems in refrigerated beverage vending cabinets
UEERA0076
Delivered by RTOsVaries by providerView unit - Unit of competencyELECTIVE
Resolve problems in transport refrigeration systems
UEERA0077
Delivered by RTOsVaries by providerView unit - Unit of competencyELECTIVE
Resolve problems in ultra-low temperature refrigeration systems
UEERA0078
Delivered by RTOsVaries by providerView unit - Unit of competencyELECTIVE
Service and repair self-contained flammable refrigerants air conditioning and refrigeration systems
UEERA0084
Delivered by RTOsVaries by providerView unit - Unit of competencyELECTIVE
Install, commission, service and maintain variable refrigerant flow air conditioning systems
UEERA0097
Delivered by RTOsVaries by providerView unit - Unit of competencyELECTIVE
Inspect, test and repair fire and smoke control features of mechanical services systems
UEERA0098
Delivered by RTOsVaries by providerView unit - Unit of competencyELECTIVE
Perform rescue from a live low voltage panel
UETDRMP007
Delivered by RTOsVaries by providerView unit
Study individual subjects from this qualification
Not ready for the full qualification? Study a single subject and credit it toward this course.
